Login
Case study · ESD quality

We protect electronic components through rigorous ESD controls and quality standards.

From goods receipt to dispatch, every batch undergoes a preventive process designed to identify risks, protect sensitive components and ensure a traceable release.

Request the case study
01 Initial challenge

Identify risks before they progress

When receiving a batch of electronic components, we identified packaging irregularities that could compromise protection against electrostatic discharge and moisture. The components could not be added to stock without verifying their conformity.

02 Implemented solution

Contain, verify and replace

We initiated incoming inspection, placed the batch on hold as a precaution and carried out ESD and MSL checks. After assessing identification, packaging and traceability, we rejected the compromised batch and arranged its replacement with conforming components.

Inspection Quarantine Verification Release
03 Preventive protection

OurObjective

Prevent potentially compromised components from reaching the customer's production line through a comprehensive electrostatic protection system: suitably equipped facilities, properly equipped personnel, controlled handling, traceability and quality verification.

Our quality process

How we protect every electronic component

ESD protection does not rely on a single measure. We integrate infrastructure, grounding, environmental control, inspection, packaging and traceability to prevent latent damage and ensure that only conforming components are released.

Control flow: Goods receipt › Inspection › Quarantine where required › Technical verification › Traceable release
01 ESD Protected Areas (EPAs)Controlled areas and ESD dissipative flooring.
Workstation within an ESD Protected Area

Illustrative image: dissipative flooring and clearly marked EPA boundaries.

WHAT WE CONTROL

Components are handled within an EPA—an ESD Protected Area—with defined access rules, materials and operations.

  • Surfaces and flooring with dissipative properties.
  • Clearly defined boundaries, signage and control of insulating items.
  • Cleaning with compatible products and periodic verification.
ANSI/ESD S20.20 · IEC 61340-5-1
02 GroundingWrist straps, ESD footwear and equipotential bonding.
Operator using ESD protection equipment

Illustrative image: ESD wrist strap connected to the common grounding point.

HOW WE PREVENT CHARGE BUILDUP

The operator, furniture and equipment are connected to a common point to maintain the same electrical potential and dissipate charge in a controlled manner.

  • Use of wrist straps and ESD footwear according to the task.
  • Continuity checks before handling components.
  • Equipotential bonding of workbenches, mats and equipment.
ANSI/ESD S20.20
03 ESD furnitureShelving, workbenches and protected surfaces.
Workbench equipped for ESD-controlled handling

Illustrative image: ESD-compatible workbench, shelving and trays.

PROTECTION AT EVERY CONTACT POINT

Workbenches, trays and shelving are integrated into the EPA to prevent components from coming into contact with surfaces that can generate or retain charge.

  • Grounded dissipative mats and surfaces.
  • Containers and trays suitable for sensitive components.
  • Segregation of incompatible packaging within the area.
IEC 61340-5-1
04 Technical inspection35 inspection checkpoints and nonconformity management.
Technical inspection of electronic components at an ESD workstation

Illustrative image: technical inspection of components within the EPA.

INCOMING INSPECTION AND DISPOSITION

Before a batch is added to stock, we review its identification, physical condition, packaging and consistency with the accompanying documentation. Any deviation triggers a precautionary hold.

  • Integrity of bags, seals, labels and markings.
  • Cross-checking of manufacturer, part number, batch and date code.
  • Recording of evidence, quarantine and nonconformity handling.
35 documented inspection checkpoints
05 Moisture controlMSL classification, storage and controlled drying.
Controlled handling of moisture-sensitive components

Illustrative image: environmental control and storage of moisture-sensitive components.

MANAGING MOISTURE-SENSITIVE COMPONENTS

Moisture sensitivity is assessed independently of ESD protection. We check that the packaging and available evidence demonstrate that components have been stored correctly.

  • MSL classification and component floor life.
  • Moisture barrier bag, desiccant and humidity indicator card where applicable.
  • Controlled storage or drying with process records.
IPC/JEDEC J-STD-020F · J-STD-033D
06 Packaging and traceabilityProtection through to delivery and document verification.
Preparation of electronic components with full batch traceability

Illustrative image: protective packaging, labelling and batch traceability.

SECURE PROCESS COMPLETION

Following technical acceptance, the batch is packed using compatible materials and linked to the documentation needed to trace its journey.

  • Shielding packaging or dissipative protection according to the risk.
  • Identification of part number, batch, quantity and special conditions.
  • Traceability across goods receipt, inspection, storage and dispatch.
Documented and traceable release

Result: the nonconforming batch is placed on hold before it reaches the customer.   ANSI/ESD S20.20 · IPC/JEDEC J-STD-020F · J-STD-033D

04 · Customer impact
Delivering

Results

01

Early detection of the issue. During incoming inspection, we identified deficiencies in the protective packaging of a batch of sensitive components. The batch was placed on hold and classified as nonconforming before being added to stock.

02

Application of ESD protection controls. Handling and inspection were carried out in protected areas, using specialised equipment and procedures based on ANSI/ESD S20.20.

03

Moisture sensitivity verification. We reviewed the MSL classification in accordance with IPC/JEDEC J-STD-020F and storage conditions against J-STD-033D. As adequate protection could not be demonstrated, the batch was rejected for delivery.

04

Reliable and traceable supply. The compromised batch was replaced with components whose packaging, identification and traceability had been verified, and which had been inspected and stored under controlled conditions.

05 · Process completion

Evidence and release criteria

Identification

Verified part number, manufacturer, batch and date code.

Protection

Conforming ESD/MSL packaging and storage conditions.

Traceability

Documented goods receipt, inspection, disposition and dispatch.

Components are only released when inspection and documentation demonstrate their conformity.

Contact us

Request the complete case of inventory assurance throughout the product lifecycle from us.

The figures that endorse us

Years
working for you
+ 35
Of Parts
supplied in 2023
+ 20 M
Customers
satisfied
+ 3900
Countries
we work with
30
Projects
in the last year
100
References
in stock
+ 70 K
REQUEST FOR A QUOTE